Menu

Industrial  Solution Provider

 

DIFFERENTIAL PROBE, 25 MHz (TT-SI-9001)

  • Bandwidth : DC to 25 MHz (-3dB)
  • Attenuation Ratio : x10 / x100
  • DC-Accuracy : ±2 %
  • Input Impedance : 4 MΩ, 5.5 pF
  • Rise Time : 14 ns
  • Measurement Category : CAT III
  • Max. Amplitude : ±7 V (into 2 kΩ load)
  • Offset : <±5 mV
  • Noise (typical) : 0.7 mVrms
  • Source Impedance (typical) : 50 Ω (for using 1 MΩ input system oscilloscope)
  • CMRR (typical) : -86 dB @ 50 Hz, -66 dB @ 20 kHz

 

MULTIMETER HIGH VOLTAGE PROBE, 300 Hz (TT-HVP-40)

  • Attenuation Ratio : x1000 @ 10 MΩ ,  x2000 @ 1 MΩ
  • Input Impedance : 1000 MΩ
  • Bandwidth : 300 Hz (-3 dB)
  • Cable Length : 1,0 m
  • Max. Input Voltage : DC 40 kV, AC 28 kVrms (0..300 Hz)

OSCILLOSCOPE PROBE, 300 MHz (TT-LF-312)

  • Attenuation Ration : x1
  • Input Impedance : MΩ, 47 pF
  • Bandwidth : 15 MHz
  • Rise Time : 24 ns
  • Cable Length : 1,2 m*
  • Compensation Range : 10..60 pF

 

DIFFERENTIAL PROBE, 25 MHz (TT-SI-9002)

  • Bandwidth : DC to 25 MHz (-3dB)
  • Attenuation Ratio : x20 / x200
  • DC-Accuracy : ±2 %
  • Input Impedance : 4 MΩ, 5.5 pF
  • Rise Time : 14 ns
  • Measurement Category : CAT III
  • Max. Amplitude : ±7 V (into 2 kΩ load)
  • Offset : <±5 mV
  • Noise (typical) : 0.7 mVrms
  • Source Impedance (typical) : 50 Ω (for using 1 MΩ input system oscilloscope)
  • CMRR (typical) : -86 dB @ 50 Hz, -66 dB @ 20 kHz

 

OSCILLOSCOPE HIGH VOLTAGE PROBE, 40 MHz (TT-HVP-08)

  • Attenuation Ratio : x1000
  • Accuracy : VDC ±2 % [+5 kV],      ±3 % [+5 kV-8 kV],     VAC ±3 % @ 1 kHz
  • Input Impedance : 100 MΩ, 3 pF
  • Bandwidth : 40 MHz (-3 dB)
  • Rise Time : 9 ns
  • Cable Length : 2,0 m
  • Compensation Range : 10..30 pF
  • Max. Input Voltage : DC 8 kV, AC 6 kVrms, PEAK 16 kV

 

DIFFERENTIAL PROBE, 70 MHz (TT-SI-9010)

  • Bandwidth : 70 MHz
  • Attenuation Ratio : x100 / x1000
  • DC-Accuracy : ±2 %
  • Input Impedance : 10 MΩ, 10 pF
  • Rise Time : 5 ns
  • Measurement Category : CAT I
  • Max. Amplitude : ±1.4 V (into 50kΩ load)
  • Offset : <±5 mV
  • Noise (typical) : 0.9 mVrms
  • Source Impedance (typical) : 50 Ω (for using 1 MΩ input system oscilloscope)
  • CMRR (typical) : -80 dB @ 50 Hz, -60 dB @ 1 MHz

 

OSCILLOSCOPE PROBE, 300 MHz (TT-HV-250)

  • Attenuation Ratio : x100
  • Input Impedance : 100 MΩ, 4 pF
  • Bandwidth : 300 MHz
  • Rise Time : 1,2 ns
  • Cable Length : 1,2 m *
  • Compensation Range : 10..50 pF
  • Max. Input Voltage : 2500Vp CAT I, DC incl. Peak AC (derating with frequency)